HBA
Adjustable LED High Bays
Series AHB is a group of adjustable LED high bay with rotatable panels allowing user to rotate panels to direct light. The optional factory-installed Signtex Emergency Lighting Control option ensures full emergency code compliance at the lowest possible cost.
- Painted steel housing and PMMA (polymethyl methacrylate) frosted lenses are standard.
- Easy installation in new construction or retrofit.
- Optics rotate up to 150°. Chain-mount kits (includes v-hooks and ⅛” thick, 1-meter long chain) are standard. Options include wire-guard kits, pendant mount kits, and surface mount kits.
- L70 hours are IES TM-21-11 calculated hours.
- Chain mounting with V-hooks is standard. Optional pendant mounting kit (p/n LEDHB-PMK-S) provides pendant attachment to ½” rigid conduit.
- Optional surface mounting kit (p/n LEDHB-SMK-S) provides attachment to solid surfaces.
- cULus listed for damp locations in ambient temperatures from -40°C to 50°C (-40°F to 122°F).
- DLC premium.
- Complies with RoHS (Restriction on Hazardous Substances) requirements.
- Complies with FCC Part 15, class A. Flicker-free per IEEE1789-2015 (no observable adverse effects of flicker at 100% light output level).
- Complies with IEC/EN61000-4-5, input transient protection (2.0kV).
CCT
- 4000K
- 5000K
CRI
- 80 CRI
Color / Finish
- White
Dimming Protocol
- 0-10 V
- Lutron
- Step-Dimming
Efficacy
- 142 lm/w
- 144 lm/w
- 147 lm/w
- 148 lm/w
- 150 lm/w
- 151 lm/w
- 152 lm/w
- 155 lm/w
- 156 lm/w
- 157 lm/w
- 158 lm/w
- 161 lm/w
Lamp Life
- 44000 hrs
- 148000 hrs
Lamp Source
- LED
Listings
- cULus
Lumens
- 1420 Lm
- 1440 Lm
- 1846 Lm
- 1872 Lm
- 3550 Lm
- 3600 Lm
- 9000 Lm
- 9886 Lm
- 9935 Lm
- 12000 Lm
- 12531 Lm
- 12681 Lm
- 15000 Lm
- 15038 Lm
- 15043 Lm
- 15495 Lm
- 15819 Lm
- 17769 Lm
- 17959 Lm
- 18000 Lm
- 19158 Lm
- 19469 Lm
- 23141 Lm
- 23645 Lm
- 24000 Lm
- 24825 Lm
- 25457 Lm
- 30000 Lm
- 30160 Lm
- 31090 Lm
Materials
- Polycarbonate
- Steel
Mounting
- Pendant
- Surface
Ratings & Compliance
- DLC
- Damp
- FCC
Voltage
- 120 V
- 240 V
- 277 V
- 347 V
- 480 V
- Emergency lighting from 1,400 Lm to 5,600 Lm with adjustable Emergency Lighting Control (ELC), powered from a Signtex low-voltage central battery system.
- Available with factory-installed UL Listed Emergency Lighting Control (ELC), for connection to a Signtex central battery, DC emergency power system.
- ELC models are available with 480VAC input option.
- Available in 4000k (neutral white) and 5000k (cool white) color temperatures.
- Long-life LEDs provide 174,000 hours of operation with at least 70% of initial lumen output (L70).
- Delivers from 15 to 30,000 lumens (140 lumens per watt, LPW).
- Universal 120-277 AC voltage (50-60Hz) is standard.
- 0-10vdc dimming drivers are standard.
- Power factor > 0.90.
- Total harmonic distortion < 20%.
- Color rendering index > 80.
Resources
- Emergency lighting from 1,400 Lm to 5,600 Lm with adjustable Emergency Lighting Control (ELC), powered from a Signtex low-voltage central battery system.
- Available with factory-installed UL Listed Emergency Lighting Control (ELC), for connection to a Signtex central battery, DC emergency power system.
- ELC models are available with 480VAC input option.
- Available in 4000k (neutral white) and 5000k (cool white) color temperatures.
- Long-life LEDs provide 174,000 hours of operation with at least 70% of initial lumen output (L70).
- Delivers from 15 to 30,000 lumens (140 lumens per watt, LPW).
- Universal 120-277 AC voltage (50-60Hz) is standard.
- 0-10vdc dimming drivers are standard.
- Power factor > 0.90.
- Total harmonic distortion < 20%.
- Color rendering index > 80.
- Painted steel housing and PMMA (polymethyl methacrylate) frosted lenses are standard.
- Easy installation in new construction or retrofit.
- Optics rotate up to 150°. Chain-mount kits (includes v-hooks and ⅛” thick, 1-meter long chain) are standard. Options include wire-guard kits, pendant mount kits, and surface mount kits.
- L70 hours are IES TM-21-11 calculated hours.
- Chain mounting with V-hooks is standard. Optional pendant mounting kit (p/n LEDHB-PMK-S) provides pendant attachment to ½” rigid conduit.
- Optional surface mounting kit (p/n LEDHB-SMK-S) provides attachment to solid surfaces.
- cULus listed for damp locations in ambient temperatures from -40°C to 50°C (-40°F to 122°F).
- DLC premium.
- Complies with RoHS (Restriction on Hazardous Substances) requirements.
- Complies with FCC Part 15, class A. Flicker-free per IEEE1789-2015 (no observable adverse effects of flicker at 100% light output level).
- Complies with IEC/EN61000-4-5, input transient protection (2.0kV).
CCT
- 4000K
- 5000K
CRI
- 80 CRI
Color / Finish
- White
Dimming Protocol
- 0-10 V
- Lutron
- Step-Dimming
Efficacy
- 142 lm/w
- 144 lm/w
- 147 lm/w
- 148 lm/w
- 150 lm/w
- 151 lm/w
- 152 lm/w
- 155 lm/w
- 156 lm/w
- 157 lm/w
- 158 lm/w
- 161 lm/w
Lamp Life
- 44000 hrs
- 148000 hrs
Lamp Source
- LED
Listings
- cULus
Lumens
- 1420 Lm
- 1440 Lm
- 1846 Lm
- 1872 Lm
- 3550 Lm
- 3600 Lm
- 9000 Lm
- 9886 Lm
- 9935 Lm
- 12000 Lm
- 12531 Lm
- 12681 Lm
- 15000 Lm
- 15038 Lm
- 15043 Lm
- 15495 Lm
- 15819 Lm
- 17769 Lm
- 17959 Lm
- 18000 Lm
- 19158 Lm
- 19469 Lm
- 23141 Lm
- 23645 Lm
- 24000 Lm
- 24825 Lm
- 25457 Lm
- 30000 Lm
- 30160 Lm
- 31090 Lm
Materials
- Polycarbonate
- Steel
Mounting
- Pendant
- Surface
Ratings & Compliance
- DLC
- Damp
- FCC
Voltage
- 120 V
- 240 V
- 277 V
- 347 V
- 480 V